Heat sealing sterilization reels: sealer settings and daily seal checks

How to set a rotary heat sealer, run the daily seal check, spot weak, burnt and channelled seals, and pack reels so seals stay intact through the cycle.

In short: a heat seal is part of the sterile barrier, so treat the sealer like any other validated process. Set the temperature the reel maker specifies, check the sealer at the start of every day with a seal check strip, and reject any pack whose seal is narrower than 6 mm, channelled, wrinkled or burnt. Leave at least 30 mm between the item and each seal.

What makes a good seal

A paper-film reel is sealed by melting the inner layer of the film onto the paper. Three settings decide the result: temperature, contact pressure and contact time (on a rotary sealer, the conveyor speed). ISO 11607-2 requires these to be validated and then monitored, and EN 868-5 sets a minimum seal width of 6 mm for paper-film pouches and reels.

SealWhat you seeLikely cause
GoodContinuous, even band at least 6 mm wide; peels cleanly with no paper fibres torn outCorrect settings, clean dry material
Weak or patchyPale or broken areas; the film lifts with little forceTemperature too low, speed too high, worn pressure rollers
Burnt or brittleBrown or glossy band; paper tears or fibres pull out when peeledTemperature too high or speed too low
ChannelledA crease or tunnel running across the sealWrinkled material, overfilled pack, item too close to the seal

Setting the sealer

  • Use the sealing temperature the reel manufacturer specifies. Paper-film reels and Tyvek®-film reels need different settings — never assume one setting suits both.
  • Let the sealer reach its set temperature before the first pack; most units show a ready signal.
  • Use a rotary sealer that controls and displays temperature, pressure and speed. Simple bar or impulse sealers are hard to validate and are not suitable for a CSSD.
  • Record the settings, and lock them if the sealer allows, so they are not changed between shifts.

Daily seal check

  1. At the start of each day, after warm-up, seal a seal check strip (a printed test sheet inside a pouch) on the normal settings.
  2. Open it and compare with the maker’s reference: the print should transfer evenly across the full width of the seal.
  3. Check the seal width is at least 6 mm along its whole length.
  4. File the strip or a photo with the date, sealer number and operator’s initials. A failed check stops sealing until the cause is found.

Repeat the check after any repair, a change of reel type or supplier, or whenever an operator sees a doubtful seal.

Packing for a clean seal

  • Leave at least 30 mm between the item and each seal so the item cannot press into it — see the reel size chart.
  • Seal only clean, dry material. Wet hands, lubricant or lint in the seal zone weaken it.
  • Remove as much air as practical before sealing, without stretching the reel.
  • For double packing, use a smaller inner pouch that sits flat inside the outer one without folding, with paper facing paper and film facing film.
  • Seal across the reel at a right angle, leaving a peel tab at the opening end.

Inspect every pack

Before loading, the packer checks each seal for gaps, channels, wrinkles and burn marks, and checks the reel’s printed process indicator is present. After sterilization, the seal is checked again: steam can open a weak seal that looked acceptable on the bench.