+92 318 5412255 +92 51 2769 848 info@prodr.com.pk Delivering nationwide
Partner desk Enquiry basket0 Contact Us

Crepe paper vs SMS non-woven wrap: which sterilization wrap to use

Crepe paper or SMS non-woven wrap? Compare steam, EO and plasma compatibility, strength, water repellence and cost, plus correct double-wrapping technique.

In short: crepe paper is a cellulose wrap — soft, economical and suitable for steam and EO, but not for hydrogen-peroxide plasma. SMS non-woven wrap is polypropylene — stronger, more water-repellent and compatible with steam, EO and plasma, at a higher price. Many CSSDs use crepe for routine trays and SMS for heavy sets or plasma loads.

Side by side

Crepe paperSMS non-woven
MaterialCreped medical-grade celluloseSpunbond–meltblown–spunbond polypropylene
StandardEN 868-2 and ISO 11607-1
SteamYesYes
Ethylene oxideYesYes
H₂O₂ plasmaNo — cellulose absorbs peroxideYes, where validated
Strength and tear resistanceGood for standard traysHigher; better for heavy sets and sharp corners
Water repellenceModerateHigh
Drape and handlingSoft, conforms well, easy to foldSoft, slightly springier
Cost per sheetLowerHigher

When crepe paper is the right choice

  • Routine instrument trays and packs for steam or EO.
  • Departments that wrap in two sheets and want a lower cost per pack.
  • Items that need a wrap that folds tightly around corners.

SteriCraft® crepe wrapping paper is supplied in standard sheet sizes for trays and sets.

When SMS is worth the extra cost

  • Hydrogen-peroxide plasma loads, which need cellulose-free packaging.
  • Heavy orthopaedic or general sets where paper tends to tear.
  • Packs moved between sites or stored on wards, where extra protection helps.

Wrapping technique matters more than the material

  1. Choose a sheet that covers the tray with enough overlap to fold all four sides fully.
  2. Wrap in two layers — sequentially or simultaneously — using an envelope or parallel fold.
  3. Close with indicator tape for the process: steam, EO or plasma.
  4. Do not over-tighten; the sterilant must reach the contents and the wrap must open aseptically.

For reels and pouches instead of wraps, see the sterilization packaging guide.